Showing results: 46 - 60 of 375 items found.
-
MGCH-2 -
Macintyre Electronic Design Associa
The MGCH-2 is the lowest noise, highest sensitivity single axis AC magnetic field sensor available for the measurement of sub radio frequency fields. Because of its innovative design, the MGCH-2 amplitude response is insensitive to the frequency of the field over its 10 Hz to 100 kHz frequency band. Accuracy at 10 kHz is 0.1 dB, and the amplitude response stays within 2 dB peak-to-peak over the bandwidth.
-
Schwarzbeck Mess Elektronik
Is an active, shielded handheld loop antenna with nearly con- stant antenna factor over the entire frequency range. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.
-
TCM-1A -
Macintyre Electronic Design Associa
The TCM-1 is a three-channel portable signal conditioner specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from either its internal batteries or the power line. It incorporates two sets of power line rejection filters, switch selectable for 50 or 60 Hz and the corresponding first four harmonics.
-
Wuntronic GmbH
The field strength measuring instruments are ideally suited for measuring magnetic field strength but also for residual magnetism (remanece)andetermination after demagnetization of metals.
-
Schwarzbeck Mess Elektronik
A System to generate magnetic fields and to perform tests regarding the susceptibility against magnetic fields.
-
Capacitance -
Lake Shore Cryotronics, Inc.
CS capacitance sensors are ideally suited for use as cryogenic temperature control sensors in strong magnetic fields because they exhibit virtually no magnetic field dependence. Displacement current is not affected by magnetic fields. Consequently, temperature control fluctuations are kept to a minimum when sweeping magnetic field or when changing field values under constant temperature operation.
-
HEM -
TOEI INDUSTRY CO, LTD.
The physical quantity of Hall Coefficient, Hall Mobility and Carrier Density etc. can be investigated by measuring at room temperature voltage occurred perpendicularly to the both magnetic field and constant-current when flowing constant-current perpendicularly to magnetic field from current source while applying magnetic field to sample set at the center of magnetic field of magnet.
-
ROM-Elektronik GmbH
The perfect way to display the three-dimensional nature of the magnetic field (eg, magnetic field). Magnaprobe is a small magnet which is rotatably mounted in two directions. The magnetic north pole is red, the magnetic south pole is dyed blue.
-
Ferrites India
Zero field cavities generate a zero magnetic field in an air gap. They are mainly used to calibrate hall probes for their zero scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using Zero Field Cavity.
-
ROM-Elektronik GmbH
For the measurement of magnetic equilibria such as the earth's magnetic field, for the determination of anomalies and biologically active location factors. Three highly sensitive magnetic field sensors, as well as a dedicated microprocessor, are integrated into the measuring probe. The sensitive magnetic field sensor is connected to a PC, notebook or laptop (not included). The main features in brief:
-
SanSys Electronic GmbH
With the 3D Helmholtz coil system, 3-dimensional magnetic field vectors can be generated. By superimposition, it is possible to create a field-free space or an artificial earth magnetic field vector inside the coil arrangement. The coil arrangement was developed for the calibration of magnetic field sensors.
-
MAGMESS Magnet-Messtechnik
Analog Magnetometer for very low magnetic fields. Measuring range: ±20 G. The solenoid-Tester detects magnetic fields by LED or buzzer.
-
CAYLAR, NMR20 Teslameter -
Caylar
The NMR20 Gaussmeter (NMR Teslameter) measures magnetic fields using the principle of nuclear magnetic resonance . This is the most precise technology for measuring the magnetic field. 1mG accuracy and 0.2ppm/year drifting.There is no temperature drift.
-
ROM-Elektronik GmbH
For measuring magnetic DC fields such as e.g. B. the earth's magnetic field and to determine anomalies and biologically effective site factors with digital precision!
-
Macintyre Electronic Design Associa
he MEDA turnkey closed loop magnetic field sources cancel the local ambient field as well as generate accurate and uniform magnetic fields in a control volume. The sources use Helmholtz coils driven by control currents to produce stable magnetic fields from 1 nT to 100,000 nT. The accuracy of the field in the control volume is better than 0.05% of the setting.